Engineer's Quick Reference - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

Appendices

Engineer's Quick Reference

Hotkey
Options
Program Panel Outputs
1
1 = Panel Output 1 (relay)
2 = Panel Output 2 (-ve)
3 = Panel Output 3 (+ve)
4 = Panel Output 4 (+ve)
Program Digicom Outputs
2
1 = Channel 1
2 = Channel 2
3 = Channel 3
4 = Channel 4
Program Digicom Channels
3
1 = Channel 1
2 = Channel 2
3 = Channel 3
4 = Channel 4
Program Circuits, Attributes & Wards
4
Circuit Types
0 = Not Used
1 = Night
2 = 24 Hour
3 = PA Silent
4 = PA Audiible
5 = Fire
6 = Auxiliary
7 = Final Exit
Circuit Attributes
1 = Access
2 = Double Knock
3 = On Test
4 = Omittable
5 = Reset
6 = Activity
7 = Entry
8 = Chime 1
B = Toggle attribute between YES/NO
Wards
1 - 8 = Select/deselect wards displayed
A/C = Toggle wards A-H or I-P
B = Select/deselect all wards
Program System Timers
5
Exit time wards A-P
Entry dly wards A-P
Digi dly wards A-P
Bell dly wards A-P
Bell dur wards A-P
Exit settle time
2nd Entry delay
Double Knock dly
Abort duration
Abort delay
2nd alarm time
Courtesy time
Access code time
Menu time-out
Line fault delay
AC off delay
Program Setting Modes
6
A/C =Select ward
1 = Final Exit
2 = Exit Terminator
3 = Timed Exit
4 = Instant
5 = Deferred
88
Engineers Menu 1
Page
34
34
5 = Channel 5
6 = Channel 6
7 = Channel 7
8 = Channel 8
34
5 = Channel 5
6 = Channel 6
7 = Channel 7
8 = Channel 8
40
8 = Exit Terminator
9 = Ward Key
A/C = Shunt Key
A/C = Tamper
A/C = Security
A/C = 24hr Silent
A/C = Night Perimeter
A/C = Custom circuits
9 = Chime 2
A/C = Chime 3
A/C = Inverted
A/C = Shuntable
A/C = Beam Pair
A/C = Eng. Test
A/C = Monitored
A/C = Non Latching
42
Monitor cct time
Beam pair time
Battery test dur
Answer ring time
Global bell dly
Global bell dur
Activity delay
Defer setting by
Battery test
Hi Security time
Cct test time
Service time
Payment time
Test call every
Select menu time
Custom o/p 2 Tmr
44
Hotkey
Options
System Print-out
7
0 = Custom text
1 = Modem data
2 = User codes
3 = Configuration
4 = Outputs
5 = Setting modes
6 = System timers
7 = Time switches
Program System Options
8
Number of rearms
Modem rings
Keys until tamp
Program Configuration
9
00 = Bell is an SAB / Bell is an SCB
01 = View alms P.Set / View alms unset
02 = Duress Disabled / Duress Enabled
03 = Engr Authorised / User Authorised
04 = On-Line Enabled / On-Line Disabled
05 = Lo-sec Engineer / Hi-sec Engineer
06 = Normal answer / Timed answer
07 = Unset ward first / Set ward first
08 = Can set with L.F / No set with L.F
09 = Can set - AC off / No set - AC off
10 = Quiet chimes / Loud chimes
11 = O/P 1 normal / O/P1 inverted
12 = Digi normal / digi inverted
13 = 4 digit codes / 6 digit codes
14 = Modem on Com1 / Printer on COM1
15 = Chime Audible / Chime Visible
16 = Manual Omits / Automatic Omits
17 = Omit Tampers No / Omit Tampers Yes
18 = O/M's mimic cct / O/M's mimic alms
19 = Log Time & Date / Log Time & Day
20 = Global Setting / Local Setting
21 = Global Unsetting / Local Unsetting
22 = 24hr Omit Global / 24hr Omit Local
23 = Ward bell time / Global bell time
24 = Latching Fire / Nonlatching Fire
25 = Online Printing / Offline Printing
26 = Timed code o/p / Latched code o/p
27 = Activity flt ok/ Activity flt Bar
28 = Latching 24hr / Nonlatching 24hr
29 = Access code only / Access all codes
30 = Answer anytime / Answer o/p 1 on
31 = NVM is Unlocked / NVM is Locked
32 = Unshunt & No exit / Unshunt & exit
33 = Ignore errors / View exit errors
34 = Mimic, All times / Mimic, set only
B = Toggle between two options
View Location Text
A
1 = Panel Location
Default NVM data
B
0 = Custom text
1 = Modem data
2 = User codes
3 = Configuration
4 = Outputs
5 = Setting modes
6 = System timers
7 = Time switches
Log Off Engineer
C
TS2500 Installation Manual
Page
44
8 = Code locks
9 = Auto-set times
A/C = Custom Circuits
A/C = Circuits
A/C = Equipment wards
A/C = Net equipment
A/C = Part set groups
45
Remote resets
Reset algorithm
Double Knocks
46
49
2 = Remote Location
49
8 = Code locks
9 = Auto-set times
A/C = Custom Circuits
A/C = Circuits
A/C = Equipment wards
A/C = Net equipment
A/C = Part set groups
A/C = Log
51

Advertisement

Table of Contents
loading