TS2500 Installation Manual
Global bell dly.
If the system is fully set and the Global/Ward Bell
configuration option (23) is set to "Global" the system will
apply this timer to all alarms for all wards, otherwise it will
use the relevant ward bell delay timer. (Default = 000
Minutes).
Global bell dur.
If the system is fully set and the Global /Ward Bell
configuration option (23) is set to "Global" the system will
apply this timer to all alarms for all wards, otherwise it will
use the relevant ward bell duration timer. (Default = 020
Minutes).
Activity delay
This timer sets the duration within which all "Activity
Monitored" circuits must be activated to ensure that the
system may be set without displaying inactive circuits.
Once the timer expires it is restarted and all "Activity
Monitored" circuits must once again be re-activated.
(Default = 060 Minutes).
Defer setting by
When using the auto-set feature users may defer setting
of the ward(s) by the amount set in this timer. (Default =
010 Minutes).
Battery test
The timer controls the frequency of the system battery
test. (Default = 060 Minutes).
Hi Security time
This timer sets the duration in which a "High Security"
ward can remain unset before it automatically
attempts to set itself. When a "High Security" ward is
unset activation of any circuit with that ward will reset this
timer. (Default = 000 Minutes).
Cct test time
This timer varies the number of days that the "Test"
attribute may be applied to a circuit. If the timer is set to
000 then circuits will remain on test until the "Test"
attribute is removed. (Default = 014 Days).
Service time
The installation company may use this timer to
periodically generate "SERVICE REQUIRED" message so
that the user is reminded that a service call is required.
The users may continue to set and unset the system.
When the engineer attends the site and enters their
passcode the message is cleared. The service timer is
re-started when the engineer re-selects this timer option.
To disable this feature set the timer to 000. (Default =
000 Days).
Payment time
The installation company may use this timer to prevent
the users from setting the system. When the timer expires
the selected ward will lock into "Engineer Reset" and the
users are unable to set the selected ward until the
engineer has reset the system or the user has been
provided with a "Remote Reset" code.
To disable this feature set the timer to 000. The payment
timer can be selectively applied to wards A to P, see
"Equipment Wards" on page 80. (Default = 000 Days).
Test call every
If the system is fitted with a plug-on digicom (DC54,
DC58 or DC58M) it is possible for the control panel to
make the digicom send a timed test call to the central
station. The "Test Call" timer sets the frequency of
activation in days. Once programmed the digicom will
send the test call at 3.00AM. (Default = 000 Days).
Select menu time
This timer determines how long the "Set/Unset" menu is
displayed after a user passcode is entered. (Default =
010 Seconds).
Custom o/p 2 tmr
This timer determines how long "Custom Output 2" will
remain active after it is triggered. (Default = 000
Seconds).
5
Engineers menu 1
System timers
Exit time ward A
A C
/
B
=next timer group
Entry dly ward B
015 Second(s)
To edit enter 3
digit number
Entry dly ward A
> 030 Second(s)
System Timers Flowchart
Engineer's Menu 1
[
Timer
030 Second(s)
Current Time
to scroll timers
Timer
Current Time
[
43