TS700 LEC

The TS700 LEC allows the facility to add an extra two
p r o gra mmab le de te c tio n c irc uits and o ne
programmable output. Up to five can be connected to
a network. The TS700 LEC would normally be used when
upgrading existing systems that have two zone
expansion devices, such as the CPA6 MKII.
PCB mounting
holes (4)
CABLE ENTRY
Programmable
detection circuits
NULL
I/D selector
CABLE ENTRY
Figure 17. TS700 LEC Layout

Installing a TS700 LEC

1.
Separate the cover and base of the LEC by using a
screwdriver to push 2 of the clips (left or right) inward
from the base indents, then lift the cover clear.
2.
If the LEC is being fitted inside the control panel
remove the LEC PCB from its base and secure it to
the base of the control panel using self adhesive
feet. If required, the tamper switch can be disabled
by fitting the jumper link across JP2, see Figure 17.
3.
If the LEC is being fitted outside the control panel,
hold the base in position and mark the two securing
holes. Drill and plug the wall, then pass all cables
into the base via the cable entry points. Secure the
base to the wall using the appropriate fixing screws.
4.
Connect network data cables to the appropriate
terminals.
5.
Conne ct d ete ctio n cir cu it ca bles t o the
appropriate terminals.
6.
Set the I/D selector jumper link to the required
position, see the table below, ensuring no two
nodes, remote keypads or LEC's on the same
network have the same I/D.
7.
Fit the PCB into the base being careful not to trap
cables or to obstruct the tamper switch.
Box mounting
holes(2)
Network
connections
Programmable output
switched -ve @100mA
JP2
TAMPER = JP2 NOT FITTED
NO TAMPER = JP2 FITTED
Tamper switch
Fit jumper-link to
disable tamper switch
TS700 LECs connected to the Network
I/D
Circuit A
1
N001
2
N009
3
N017
4
N025
Null
N033
N = Network Number (1 - 8)

TSLEC8

The TSLEC8s are designed to fit inside the control panel,
each LEC allows the facility to add an extra eight
programmable detection circuits to the system.
Mounting space and holes have been provided inside
the control panel to allow two TSLEC8s to be fitted. The
TSLEC8s are assigned to "Network 0".
Programmable
detection circuits
Figure 18. TSLEC8 Layout

Installing the TSLEC8

1.
Insert the four mounting pillars provided into the four
holes in the TSLEC8 and secure in the base of the
control panel.
2.
Connect one end of the interface lead into the
TSLEC8 and the other into the control panel
connector LEC 1 (detection circuits 0001 to 0008) or
LEC 2 (detection circuits 0009 to 0016).
3.
Connect detection circuit wiring to the appropriate
terminals.
System Installation
Circuit B
Output
N002
N01A
N010
N02A
N018
N03A
N026
N04A
N034
N05A
Programmable
detection circuits
To control panel
plug LEC1 / LEC2
25