TS2500 Installation Manual
50
PC Output 2 On
This output is controlled by a PC with Lineload
software.
51
PC Output 3 On
This output is controlled by a PC with Lineload
software.
52
PC Output 4 On
This output is controlled by a PC with Lineload
software.
53
Service Required
Activates when the "Service Time" has expired,
deactivates when the engineer passcode is
entered.
54
Reset Required
Activates when the system requires an "Engineer
Reset", deactivates when the system is reset either
by the engineer or Remote Reset.
55
Always Off
This output never activates
56
Duress Alarm
Activates when a duress code is entered,
deactivates when the duress alarm is reset.
57
System Part Set
Activates when any part of the system is set,
deactivates when all wards are unset or the
system is fully set.
58
Battery Fault
Activates when a battery fault occurs, deactivates
when the fault is cleared.
59
Set Failed
Activates when any ward fails to set, deactivates
when the set fail condition is reset.
60
System Open
Activates when the system is unset, deactivates
when any part of the system is set.
61
Shunt code
Activates for 5 seconds when a shunt code is
entered.
62
Random Output On
Activates randomly (between 5 and 60 minutes).
63
Modem Lockout
Activates when the modem is locked-out (four
failed attempts), deactivates when a master
code is entered or after 4 hours.
64
Auxiliary 1 tamp
Activates when auxiliary tamper 1 is activated,
deactivates when the alarm is reset.
65
Auxiliary 2 tamp
Activates when auxiliary tamper 2 is activated,
deactivates when the alarm is reset.
66
Bell box tamper
Activates when the bell tamper is triggered,
deactivates when the alarm is reset.
67
Panel lid tamper
Activates when the panel lid tamper is activated,
deactivates when the alarm is reset.
68
Chime Mimic
Activates for 2 seconds when any chime circuit is
activated.
69
24hr CCT Omitted
Activates when any 24Hr circuit is manually
omitted, deactivates when all omitted circuits are
reinstated.
70
Monitored O/P On
Activates when a monitored circuit is triggered
and stays active for the duration of the "Monitor
Cct Time".
71
Alarm Abort
Activates for the duration of the "Abort duration"
timer when the alarm has been aborted by the
user .
72
Code Lock 1 on
Activates when "Code lock timer 1" is on,
deactivates when the timer is off.
73
Code Lock 2 on
Activates when "Code lock timer 2" is on,
deactivates when the timer is off.
74
Code Lock 3 on
Activates when "Code lock timer 3" is on,
deactivates when the timer is off.
75
Rem call enabled
Activates when a user enables remote service
call, deactivates when a user disables remote
service call or after four hours.
76
Auto-set timer 1
Activates when the "Auto-set timer 1" is on,
deactivates when timer is off.
77
Auto-set timer 2
Activates when the "Auto-set timer 2" is on,
deactivates when timer is off.
78
Auto-set timer 3
Activates when the "Auto-set timer 3" is on,
deactivates when timer is off.
79
Relearn Required
Activates when the system requires a relearn,
deactivates when the relearn has been
performed.
80
Custom cct 1
Activates when the custom circuit 1 is triggered,
deactivates when custom circuit 1 is reset.
81
Custom cct 2
Activates when the custom circuit 2 is triggered,
deactivates when custom circuit 2 is reset.
Engineer's Menu 1