Monitoring A Remote Power Supply - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

System Installation
+ve O/P
(Programmed as Alarm / Bell / etc)
Aux 0V
+ve O/P
(Programmed as Detector Reset)
Aux 0V
+ve O/P
Aux 0V
+ve O/P
Aux 0V
+ve Outputs

Monitoring a Remote Power Supply

The TS2500 can be configured to monitor a 519XB
power supply unit using a 519FM fault monitor PCB. The
519FM plugs directly onto the 519XB PCB plug labelled
JP1.
The 519FM PCB monitors any combination of:
Supply Failure (mains)
l
Low Battery Voltage
l
12V Failure (fuse failure)
l
In order to monitor all the above fault conditions, the
outputs on the 519FM must be connected to three
detection circuits. It is recommended that the circuits
are programmed as custom circuits as shown in Figure
30. For details on configuring "Custom Circuits", see
page 72.
If required, the PSU battery can be "load tested"
periodically by connecting a switched +ve output to
the 519FM BATT TEST terminal. The battery test occurs at
pre-programmed intervals and every time the engineer
logs off the system.
30
Relay available from
Diode (IN418)
RS components
P/No. 346-946.
Relay
Capable of switching
mains voltages
+ 12 V
0V
Smoke
Detector
1K0 Ohm Resistor
LED (Light Emiting Diode)
12V Buzzer
RS Part No. 245-051
Figure 29. Output Examples
Aux 12 V
-ve O/P
(Programmed as Alarm / Bell / etc)
+ 12 V
Aux 12V
-Ve O/P
(Programmed as Detector Reset)
Aux 12V
-Ve O/P
Aux 12V
-Ve O/P
-ve Outputs
Program As:-
ZA
Custom
Circuit 1
TA
ZB
Custom
Circuit 2
TB
NODE
ZC
Custom
Circuit 3
TC
Battery
A+
Test (045)
O/P
Aux 0V
Custom Circuit Programming
Bell Digi Sounder Warning
Yes
Custom
Circuit 1
Yes
Custom
Circuit 2
Yes
Custom
Circuit 3
Figure 30. Monitored Power Supply Connections
TS2500 Installation Manual
Relay available from
Diode (IN418)
RS components
P/No. 346-946.
Relay
Capable of switching
mains voltages
0V
Smoke
Detector
1K0 Ohm Resistor
LED (Light Emiting Diode)
12V Buzzer
RS Part No. 245-051
Supply
Fail
Battery
Low
12V
Fail
Batt Test
0V
519 FM
Circuit Text
Custom o/p
In Unset
In Part Set
PSU A.C. Fail
In Full Set
In Unset
In Part Set
PSU Batt. Fault
In Full Set
In Unset
In Part Set
PSU Fuse Fail
In Full Set