System Wiring

All ZONE and TAMPER inputs are linked out prior to
despatch from the factory. Remove these links from
those zones which are to be used, but leave the links in
unused zones.
The EXIT TERMINATOR link MUST BE
REMOVED even if this facility is not used, otherwise all
programmed information will be lost on total power loss
(mains and battery).
PLANNING AND INSTALLING THE WIRING:-
1.
Ensure that the mains cable, circuit cables and
telecom cables are kept separate, and that mains
cable enters the housing as near to the fused
terminal block as possible.
2K2
+
STROBE
-
Fig 2 SAMPLE Wiring Diagram (showing Double Pole and End of Line Resistor wiring)
496525 Issue A
4K7
2K2
ALM
ALM
TO
ZONE
TAMP
TAMP
2K2 (2200) OHMS
RED RED RED
END OF LINE RESISTOR
4K7 (4700) OHMS
YELLOW VIOLET RED
SHUNT RESISTOR
Normally
Closed
P .A. Button
S.A.B/SIREN
-VE TAMPER RETURN
+12 V
0V
- VE STROBE TRIGGER
-VE BELL TRIGGER
2.
Ensure that the circuit, tamper and remote keypad
cables are not routed adjacent to AC or RF cabling
and are not run in multicore cables with bells or
sounders.
3.
Insulation testing should only be carried out when
the cable under test is disconnected from
electronic circuitry at both ends.
NOTE: TS500 Aux TMP = Main & Bell TMP
+12V
0V
MOVEMENT DETECTOR
ALARM
WIRED END OF LINE
TAMPER
MAGNETIC
Alarm
CONTACT
WIRED
DOUBLE POLE
Tamper
Normally
Open
Keyswitch
ALARM
TAMPER
3 of 10
OP1
= WLK TST
OP2
= SW 12V
AC
IN
+
AUX 12V
-
ZONE 1
4K7
2K2
TAMP 1
ZONE 2
TAMP2
ZONE3
TAMP 3
ZONE 4
TAMP 4
Normally
Open
ZONE 5
Pushbutton
TAMP 5
EXIT TERM
KEYSW/
F. EXIT
P .A.
AUX TMP
BELL TR -
O/P1
O/P2
+
H/O
-
STB -
TRG -
L/S+
16 0HM
LOUDSPEAKER
TS510 & TS500
TS510 & TS500

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts500

Table of Contents