EPSON Stylus Pro 7400/7800/9400/9800
1.4.4.29 Total Prints
The "Total Prints" displays a cumulative number of printed pages by decimal number
up to 6-digit.
1.4.4.30 Service Life
Cutter life
Calculation method
The cutter life is guaranteed for 2,000 times of cutting operations. Each
cutting operation is counted as one time regardless of the paper size.The
remaining life is indicated based on the usage counter and the guaranteed
2,000 times of life.
Panel Display (remaining ratio of the life)
100 to 81 %
E∗∗∗∗∗F
80 to 61 %
E∗∗∗∗ F
60 to 41 %
E∗∗∗ F
40 to 21 %
E∗∗
20 to 1 %
E∗
less than 1 %
E
Maintenance call
Not occurs due to the following reasons.
The cut result shows the degree of cutter consumption.
No fatal accident is caused.
The user can replace cutters easily.
Fatal error
Not occurs
Counter clear
Cleared by replacing the cutter using the "Cutter Replacement" in the
MAINTENANCE menu.
This life counter should be used as a guideline. As the actual life of
C H E C K
P O I N T
the cutter varies depending on various factors, it must be replaced
on the basis of observed conditions.
Product Description
F
F
F
CR Motor life
Calculation method
The life of the CR motor is regarded as that of the Ink Supply Tube because a
malfunction of the tube due to its wear can cause a serious failure of the CR
motor. The guaranteed life of the Ink Supply Tube is defined by the number of
Carriage movement cycles, so the remaining amount of the CR motor life is
obtained based on the Carriage movement cycles.
Stylus Pro 7400/7800
Stylus Pro 9400/9800
Panel Display (remaining ratio of the life)
100 to 81 %
80 to 61 %
60 to 41 %
40 to 21 %
20 to 1 %
less than 1 %
Maintenance call
Occurs when the remaining life becomes less than 4%.
Fatal error
A service call error occurs when the remaining life becomes 0 to inform that
the Ink Supply Tube must be checked for any damage.
Counter clear
Cleared by executing the "Reset When CR Unit Change" in the Adjustment
Program.
These values are intended to assist service personnel only.
C H E C K
P O I N T
Do not explain the meaning of the display to users.
Control Panel
Table 1-45. Reference Values
Model
CR Movement Cycles
1,820,000
3,150,000
E∗∗∗∗∗F
E∗∗∗∗ F
E∗∗∗ F
E∗∗
F
E∗
F
E
F
Revision B