EPSON Stylus Pro 7400/7800/9400/9800
Electric
Fatal errors of up to 7 maintenance items recorded as history can be checked. (CPU
error is not recorded.)
Counter display
The counters shown in the table below are displayed. The number is displayed in
hexadecimal.
Table 1-55. Counter Display Items and Units
Maintenance
Waste ink counter
Waste ink counter 2
Wiping times
Rubbing times
Paper Set Lever releasing frequency
Front cover opening/closing frequency
Left and right Ink Lever operating
frequency
CR motor reciprocating times
PF motor travel distance
Number of printed pages
Cleaning times
Discharged amount of ink
(A to H columns)
Cutting times
Cutter Solenoid operating frequency
Serious errors display
Displays error codes of fatal errors. The latest error is 0 and 7 errors are recoreded
in 0 to 6.
Cutting Pressure Adjustment
Adjusts the cutter pressure of the cutter. The pressure can be set in increments of 1%.
Product Description
Unit
0.02g
0.02g
Number of times
Number of times
Number of times
Number of times
Number of times
Number of times
TBD
Number of print
Number of times
Mega dot
Number of times
Number of times
Control Panel
Actuator 2
This allows you to check the operation of the Cutter Solenoid, Pump motor, Regulator
Solenoid, and Pressure motor. When you return to the menu screen after the checking
is completed, "Please Turn Off" is displayed on the LCD panel.
Edge Sensor Level Measurement
Measures the platen level (reflecting amount) detected by the paper edge sensor. When
paper is on the rear sensor, the sensor detects the paper width and obtains information
for each paper type. If paper is not on the rear sensor, the sensor obtains information for
each paper type at previous paper width detection.
Panel operations are disabled during executing the measurement. The measured result
is displayed as shown in the table below.
No measurement
Minimum
paper
measurement value
detection position
Threshold value at
Paper presence at
paper detection
paper detection
The platen level measurement is conducted from the home side to the anti-home side.
When it is completed, the Carriage moves to the position where the highest level
(reflection) is detected and stops there for three seconds.
Automatic Gap Adjustment
Makes Uni-D and Bi-D (PG 1.6mm/PG 0.8mm) adjustments.
This function automatically prints adjustment patterns in Uni-D and Bi-D, and detects
the highest density point on the printed patterns to automatically reflects the Uni-D and
Bi-D correction values.
The correction value for the Bi-D (PG 0.8 mm) is copied for the Bi-D (PG 1.2 mm) and
the Bi-D (PG 1.6mm) correction value is copied for the Bi-D (PG 2.1mm/PG2.6mm)
Revision B
Minimum value
Maximum
Maximum value
measurement value
detection position
Paper absence at
D/A value used at
paper detection
paper detection
OK/NG