EPSON Stylus Pro 7400/7800/9400/9800
5.6.3 Reset When CR Unit Change
Procedure
1.
Turn the printer ON.
2.
Start up the Adjustment Program and select [Reset When CR Unit Change].
3.
Click the [Run] button to reset the CR Motor life counter.
4.
Click the [Finish] button.
Figure 5-106. [Reset When CR Unit Change] Screen
Adjustment
5.6.4 Reset When Cleaning Unit Change
Procedure
1.
Turn the printer ON.
2.
Start up the Adjustment Program and select [Reset When Cleaning Unit
Change].
3.
Click the [Run] button to reset the Cleaning Unit change counter.
4.
Click the [Finish] button.
Figure 5-107. [Reset When Cleaning Unit Change] Screen
Reset Counters
Revision B