EPSON Stylus Pro 7400/7800/9400/9800
24. Load an A4-sized Archival Matte Paper vertically on the paper tray, and click [Next] to
print the first page (Sheet1) of the verify chart.
Never touch the printed calibration chart.
C A U T I O N
25. When the first page of the verify chart is printed to the last, load an A4-sized Archival
Matte Paper vertically on the paper tray, and click [Next] to print the second page
(Sheet2) of the verify chart.
26. Make sure that there is no missing dot in the verify chart.
If there is any defect, click [Print Verify Chart Again]. The verify chart will be printed
again after performing cleaning.
If there are no missing dots, let the chart stand for five minutes until it dries out paying
attention not to touch the chart
27. When the verify chart dries out (after five minutes), click [Next].
28. Connect the calibrator to the computer, and click [Measure].
29. Place the calibrator on the calibration base plate, and click [Calibrate].
30. Keep the calibrator remain set on the base plate, hold down the button on the side of
the calibrator until it beeps.
Once the calibration completed normally, following screen appears.
Adjustment
Basic Adjustment
Figure 5-76. Entire Process Screen
Revision B