EPSON Stylus Pro 7400/7800/9400/9800
4.2.7.3 HOLDER ASSY., IC, RIGHT,
HOLDER ASSY., IC, LEFT
HOLDER ASSY., IC, RIGHT
1.
Remove the R SIDE COVER ASSY.
2.
Release the four TUBE, SUPPLY, INK from the four retaining tabs and the
retaining clip.
Make sure that the four TUBE, SUPPLY, INK are routed behind
the screwed tab.
Right Front of the Printer
Screwed tab
Figure 4-118. Routing the TUBE, SUPPLY, INK
3.
Disconnect the four FFCs from the CSIC RELAY BOARD.
4.
Lower the I/C, LOCK LEVER.
5.
Remove the piece of the acetate tape that secures the harness of the I/C LEVER
SENSOR R.
6.
Release the two tabs that secure the I/C LEVER SENSOR R and remove it.
7.
Remove the connector from the I/C LEVER SENSOR R.
Disassembly & Assembly
See Section 4.2.3.4 on page 223.
Disassembly Procedure
Retaining clip
TUBE, SUPPLY, INK
I/C, LOCK
LEVER
4
HOLDER ASSY.,
Acetate tape
IC, RIGHT
I/C LEVER
SENSOR R
6: Tabs
Figure 4-119. Releasing the TUBE, SUPPLY, INK and Removing the I/C LEVER
Revision B
2: Retaining tabs
Connector
Connector
SENSOR R
FFC
275