System and Log Messages
Message:
ERROR: msgsnd() failed. errno=%d. destKey= 0x%x q=%d total send errors %d\
n
Meaning:
Failed to send an IPC message.
Corrective
Log in and use the "ipcs -qa" command.
Action:
Look for the message queue with the matching key.
Determine if the queue is full. If it is, then restart that process or the server
software.
If the message queue doesn't exist, then restart the process which reads
messages from that queue.
The system may be out of messages.
Message:
[%d] Unknown event queue to process[%d].
Meaning:
An IPC message contains an unknown message queue ID
Corrective
Check the configuration in processTable.cfg. Make sure the event queue and
Action:
process are listed. Then check the process is running using the "dcbps" command
line utility. If that looks good, then restart the software.
Message:
No entry for the process %s ",interface.c_str()
Meaning:
There was no record in processTable.cfg for the named process
Corrective
Either load a known good backup copy of processTable.cfg or manually edit it to
Action:
add the information for the missing process.

INIT Messages

Message:
Meaning:
There was no record in processTable.cfg for the named process.
Corrective
Either load a known good backup copy of processTable.cfg or manually edit it to
Action:
add the information for the missing process.
Message:
started process=<%s> with pid=<%d>. Args=<%s/%s>
Meaning:
This is only an error if preceeded by a message saying a process ended (killed,
aborted, exited, etc
Corrective
If a process is frequently restarting, it could be caused by: 1. Lack of some
Action:
resource, 2. A timeout, 3. Internal error. Restart the software
294 Administration and Maintenance of the S6200/S6800 Servers