Hardware Error Log Entries And Test To Clear Values - Avaya G250 Maintenance Manual

Media gateways
Hide thumbs Also See for G250:
Table of Contents

Advertisement

Avaya Communication Manager controlled maintenance
The DS1 tie trunk maintenance strategy covers logging DS1 tie trunk hardware errors, running
tests for trunk initialization, periodic and scheduled maintenance, system technician-demanded
tests, and alarm escalation and resolution. Three different trunk service states are specified in
DS1 tie trunk maintenance:
Out-of-service
In-service
Disconnect
(ready-for-service)
If the DS1 Interface media module is out of service, then all trunks on the DS1 Interface media
module are also placed into the out-of-service state and a Warning alarm is raised.

Hardware Error Log Entries and Test to Clear Values

Table 95: DS1 Tie Trunk Maintenance Error Log Entries
Error
Aux
Type
Data
0*
0
1(a)
57476
57477
57485
57487
15(b)
Any
18(c)
0
19(d)
0
130(e)
257(f)
57473
57474
513(g)
57392
200 Maintenance for the Avaya G250 and Avaya G350 Media Gateways
The trunk is deactivated and cannot be used for
incoming or outgoing calls.
The trunk is activated and can be used for both
incoming and outgoing calls.
The trunk is in an activated state but can only be
used for an incoming call.
Associated Test
Any
Port Audit and
Update Test (#36)
busyout trunk grp/
mbr
None
None
DS1 Tie Trunk
Seizure Test (#136)
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
ON
MIN/MAJ
Test to Clear Value
test trunk grp/mbr
release trunk grp/
mbr*
test trunk grp/mbr
1 of 2