Avaya G250 Maintenance Manual page 144

Media gateways
Hide thumbs Also See for G250:
Table of Contents

Advertisement

Avaya Communication Manager controlled maintenance
Table 58: TEST #35 Port Diagnostic Test (continued)
Error
Test
Code
Result
61446
FAIL
61456
FAIL
61472
FAIL
PASS
Any
NO
BOARD
144 Maintenance for the Avaya G250 and Avaya G350 Media Gateways
Description/ Recommendation
Battery feed test failed. A loop current fault was detected. This is most
probably an incoming CO-line problem. This failure code is only reported
by the TN2139 Italian DID media module.
Check the incoming CO-line for loop current. If none is detected refer the
problem to the CO.
If the CO-line checks out OK, the failure must be on the DID port.
Replace the media module.
Battery feed test failed. An on-board problem was detected. This port is
out-of-service.
Replace media module.
Battery feed test failed. A problem with the incoming CO-line was
detected.
Check the incoming CO-line for proper operation. If warranted, refer the
problem to the CO.
If the CO-line is not at fault, the failure must be on the DID port. Replace
the media module.
Current flow was detected for this port.
User-reported troubles on this port should be investigated using other
port tests and by examining connections.
Refer problem to the CO.
The test could not relate the internal ID to the port (no board).
Check to ensure that the board translations are correct. Translate the
board, if necessary.
Use the busyout board command.
Use the reset board command.
Use the release busy board command.
Use the test board command. This should re-establish the linkage
between the internal ID and the port.
If the problem persists, replace the circuit pack.
2 of 2