Avaya Communication Manager controlled maintenance

Port Audit and Update Test (#36)

This test sends port level translation data from switch processor to the DS1 Interface media
module to ensure that the trunk's translation is correct. Translation updates include the following
data: trunk type (in/out), dial type, timing parameters, and signaling bits enabled. The port audit
operation verifies the consistency of the current state of the trunk kept by the DS1 Interface
media module and the switch software.
Table 97: TEST #36 Audit and Update Test
Error
Test
Code
Result
ABORT
1000
ABORT
1006
ABORT
2000
ABORT
2100
ABORT
FAIL
204 Maintenance for the Avaya G250 and Avaya G350 Media Gateways
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test were not available. The port
may be busy with a valid call.
Use the display port GGGVSpp command to determine the trunk group/
member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up.
If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
The test was aborted because the trunk is out of service.
Use the status trunk command to verify that the trunk is out of service.
If the trunk is out of service, determine why.
If it is OK to put the trunk back in service, use the release trunk
command to put the trunk back in service, and then retry the test.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals a maximum of 5 times.
Internal system error.
Retry the command at 1-minute intervals a maximum of 5 times.