Port Diagnostic Test (#35)

This test checks a port's battery feed circuitry for on-/off-hook detection, battery shutdown, and
battery reversal (wink) capabilities.
Table 58: TEST #35 Port Diagnostic Test
Error
Test
Code
Result
ABORT
1000
ABORT
1004
ABORT
1018
ABORT
2000
ABORT
2100
ABORT
Description/ Recommendation
System resources required to run this test were not available.
Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test were not available. The port
may be busy with a valid call.
Enter display port GGGVSpp command to determine the trunk group/
member number of the port. Use the status trunk command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
If the port status is active but the port is not in use (no calls), check the
error log for Error Type 513. The port may be locked up.
If the port status is idle, busyout and release the trunk, and retry the
command at 1-minute intervals a maximum of 5 times.
If the test continues to abort, check for wiring errors toward the CO which
may cause the trunk to lock up.
If the wiring is good and the test continues to abort, replace the circuit
pack.
The port was seized by a valid call during the test.
Enter display port GGGVSpp to determine the station extension,
attendant number, or trunk group/member number of the port. Use the
status station, status attendant, or status trunk command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
Retry the command at 1-minute intervals a maximum of 5 times.
Test disabled via administration. Verify that the Maintenance Tests?
field on the Trunk Group Form is set to n. To enable the test, use the
change trunk-group x command (x is the trunk group number). Then
change the entry in the Maintenance Tests? field to y.
Response to the test was not received within the allowable time period.
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals a maximum of 5 times.