Avaya Communication Manager controlled maintenance
If all administration errors between the switch and the far-end match, and these errors
continue to recur, follow normal escalation procedures.
(b) Error Type 15—This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors (if any).
(c) Error Type 18—The DS1 tie trunk has been busied out by a busyout trunk grp/mbr
command. No calls can be made on this trunk except for the Facility Access Test Call.
Facility Access Test Calls are described in Chapter 6 and in Administrator's Guide for
Avaya Communication Manager, 555-233-506.
(d) Error Type 19—This error type indicates that the far-end may be out-of-service, or the
Electronic Tandem Network may be busied out.
(e) Error Type 130—This error type indicates that the media module has been removed or
has been insane for more than 11-minutes. To clear the error, reinsert or replace the media
module.
(f) Error Type 257—The DS1 Interface media module detects a hardware error on the DS1
tie trunk. The trunk cannot communicate with the far end because it is unable to interpret
digits sent from the far-end switch. The Aux Data field indicates the following:
Check with the far-end switch or operating company for proper trunk connection.
(g) Error Type 513—DS1 Interface media module detects a hardware error on the DS1 tie
trunk. The trunk is in-service/active and waiting for an "on-hook" from the far-end switch.
No calls can be routed over the trunk while it is in this state. Aux Data 57392 indicates no
external release on PBX disconnect. Check with the far-end switch or operating company
for proper trunk connection.
(h) Error Type 769—The DS1 Interface media module detects a hardware error on the
DS1 tie trunk. This error usually occurs after an occurrence of error type 513. The trunk
has received the belated "on-hook" that it has been waiting for from the far-end switch. The
trunk is restored to in-service/idle and can be used for calls. Aux Data 57393 indicates
delayed external release on PBX disconnect. This error can be ignored.
(i) Error Type 1793—The DS1 Interface media module is out-of-service. See MG-DS1
Maintenance documentation for details.
(j) Error Type 2305—Reorder message. The trunk could not be seized. This error causes
the Trunk Seizure Test (#136) to run and is only a problem if the Seizure Test fails (in which
case Error Type 1025 also appears). In this case, the trunk may be put in
"Ready-for-Service" state (shown as "disconnected" by the status command), which allows
only incoming calls. Run the Trunk Seizure Test (#136) and follow its procedures.
202 Maintenance for the Avaya G250 and Avaya G350 Media Gateways
57473
The rotary dial rate is below 8 pulses per second.
57474
The rotary dial rate is above 12 pulses per
second.