Avaya Communication Manager controlled maintenance
This second part of this test cannot be run on a trunk if one of the following cases is true:
The trunk direction is administered as an incoming only trunk.
The trunk is the 24th port on a DS1 Interface media module which is administered using
24th Common Channel Signaling.
The trunk has been seized by a normal trunk call.
The trunk is administered with maintenance test disabled.
The outgoing signal type of the trunk is either automatic or immediate-start.
This test always passes if the associated board is the TN802 IP trunk media module.
Table 98: TEST #136 DS1 Tie Trunk Seizure Test
Error
Test
Code
Result
ABORT
1000
ABORT
1004
ABORT
206 Maintenance for the Avaya G250 and Avaya G350 Media Gateways
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test were not available. The
port may be busy with a valid call.
Use the display port GGGVSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is in use, wait until
the port is idle before testing.
If the port status is active but the port is not in use (no calls), check
the error log for error type 1025 (see the error log table for a
description of this error and required actions). The port may be locked
up.
If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
Far end is seizing the trunk while the test is ongoing. A glare situation
is detected. Current test is designed to be aborted.
Use the display port GGGVSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is in use, wait until
the port is idle before testing.
If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.