(k) Error Type 2562—Retry Failure error. This error is logged only. It is not a hardware
failure and hence does not start any testing or generate any alarms. This error comes from
call processing and is generated when a second attempt (retry) to seize an outgoing trunk
fails.
(l) Error Type 2817—Glare error. This error is logged only. It is not a hardware failure and
hence does not start any testing or generate any alarms. This error is the result of a
simultaneous seizure of a two-way trunk from both the near-end and the far-end. Attempt
to place the call again. If the error persists, execute the DS1 Tie Trunk Seizure Test (#136)
and follow its outlined procedures.
(m) Error Type 3840—Port Audit and Update Test (#36) failed due to an internal system
error. Enter status trunk command and verify the status of the trunk. If the trunk is
out-of-service, then enter release trunk command to put it back to in-service. Retry the
test command.
System Technician-Demanded Tests: Descriptions and Error
Codes
Always investigate tests in the order presented in the table below when inspecting errors in the
system. By clearing error codes associated with the NPE Crosstalk Test, for example, you may
also clear errors generated from other tests in the testing sequence.
Table 96: System Technician-Demanded Tests
Order of Investigation
NPE Crosstalk Test (#6)
Note: This Test will abort with Error Code 1412
Conference Circuit Test (#7)
Note: This Test will abort with Error Code 1412
DS1 Tie Trunk Seizure Test (#136)
Port Audit and Update Test (#36)
*D = Destructive; ND = Nondestructive
TIE-DS1 (DS1 Tie Trunk)
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
Issue 1.1 June 2005
D/ND*
ND
ND
ND
ND
203