Digital Station Audits Test (#17) - Avaya G250 Maintenance Manual

Media gateways
Hide thumbs Also See for G250:
Table of Contents

Advertisement

Avaya Communication Manager controlled maintenance
Table 66: TEST #16 DIG-LINE Station Lamp Updates Test (continued)
Error
Test
Code
Result
PASS
Any
NO
BOARD

Digital Station Audits Test (#17)

This is a series of six tests that are classified as audits. Messages are sent to the on-board
microprocessor to perform the following tests. These audits run only if the station is in-service.
Switchhook Inquiry Test — This is an update of the call records according to the media
module's records. This inquiry is sent all the way to the voice terminal.
Bad Scan Inquiry Test — A message is sent uplink which contains a count that is
generated due to certain events relating to the link conditions. This can be an indication of
communications problems between the Processor and Digital Port media module.
For MM712, the status of the EPF is sent uplink. Possible conditions are: EPF-on-ok,
EPF-off, and EPF-no-load.
ID Request Test — A request is made to the station for its status. The station sends its
configuration information and health information back. This information is checked and a
pass/fail result is provided.
Ringer Update Test — This updates the digital telephone ringer state according to the
processor records.
DTMF Administration Update Test — This is a message to the digital station to refresh the
default value that causes the station to send touch- tones only in the primary information
channel. This value is set initially when the station is put in-service and every time the
station's state changes from other states to in-service.
158 Maintenance for the Avaya G250 and Avaya G350 Media Gateways
Description/ Recommendation
The message to light all of the station lamps was sent successfully to the
port.
Observe the station lamps being lit when running the test. If all lamps do
not light, the other Digital Line test results may indicate related problems
that do not allow the lamps to light.
Investigate by using other Digital Line port tests, and by examining the
station, wiring, and connections.
The test could not relate the internal ID to the port.
Check to ensure that the board translations are correct. Translate the
board, if necessary.
Use the busyout board command.
Use the reset board command.
Use the release busy board command.
Use the test board command. This should re-establish the linkage
between the internal ID and the port.
If the problem persists, replace the circuit pack.
2 of 2