Table 38: TEST #48 Station Present Test (continued)
Error
Test
Code
Result
PASS
Any
NO
BOARD

CO-DS1 (DS1 CO Trunk)

Table 39: CO-DS1 (DS1 CO Trunk)
MO Name (in
Alarm Log)
CO-DS1
CO-DS1
CO-DS1
Note: For Avaya G250/G350 systems you must consult local records for the
location and designation of the equipment rack where the G250/G350 is mounted.
A Major alarm on a trunk indicates that alarms on these trunks are not
**
downgraded by the set options command and that at least 75 percent of the
trunks in this trunk group are alarmed.
Description/Recommendation
The station is connected properly to the switch. Investigate
user-reported troubles on this port by running other port tests, by
examining station wiring, or by inspecting the station.
This test may also pass if no terminal equipment is connected and the
terminal is located very far from the switch.
The test could not relate the internal ID to the port (no board). This
result could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
Check to make sure that the board translations are correct. Use the list
configuration command, and resolve any problems.
If the board is correctly inserted, use the busy board GGGVS
command.
Use the reset board GGGVS command.
Use the release board GGGVS command.
Use the test board GGGVS long command. This re-establishes the
link between the internal ID and the port.
If this is not the case, check to make sure that a valid board is inserted.
Alarm
Initial Command to Run*
Level
MAJOR**
test trunk group# member# l
MINOR
test trunk group# member# l
WARNING
test trunk group# member#
CO-DS1 (DS1 CO Trunk)
3 of 3
Full Name of
MO
DS1 CO Trunk
DS1 CO Trunk
DS1 CO Trunk
Issue 1.1 June 2005
111