Avaya Communication Manager controlled maintenance
Table 56: DID Trunk Error Log Entries (continued)
Error
Aux
Type
Data
15(e)
Any
18
0
130(f)
257(g)
57472
257(h)
57473
257(i)
57474
257(j)
57475
513(k)
57392
513(l)
57393
769
Any
1537
Any
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
**Major alarms may be downgraded to Warning alarms based on the value used in the set
options command.
Notes:
See also the preceding section on trunk problems without errors or alarms.
(a) This condition occurs when the tone detector times out waiting for digits. Change wink/
immediate-start parameter to wink/immediate-start and rotary/tone-dial parameters.
1. Verify trunk administered wink/immediate-start parameter.
2. Test trunk using BUTT set.
3. Refer problem to CO.
140 Maintenance for the Avaya G250 and Avaya G350 Media Gateways
Associated Test
Alarm
Level
Port Audit
Update (#36)
busyout trunk
WRN
grp/mbr
None
WRN
None
WRN
None
WRN
None
WRN
None
WRN
None
MIN/
WRN**
None
Port Diagnostic
MIN/
(#35)
WRN**
Port Diagnostic
MAJ/ MIN/
(#35)
WRN**
On/Off
Test to Clear Value
Board
OFF
release trunk grp/mbr
ON
test trunk grp/mbr
OFF
OFF
OFF
OFF
OFF
ON
test port GGGVSpp r 3
OFF
test port GGGVSpp r 3
2 of 2