System Technician-Demanded Tests: Descriptions And Error Codes; Digital Line Electronic Power Feed Test(#11) - Avaya G250 Maintenance Manual

Media gateways
Hide thumbs Also See for G250:
Table of Contents

Advertisement

System Technician-Demanded Tests: Descriptions and Error
Codes
Always investigate tests in the order presented in the table below. By clearing error codes
associated with the Voice and Control Channel Local Looparound Test, for example, you may
also clear errors generated from other tests in the testing sequence.
Table 64: Order of Investigation
Order of Investigation
Digital Terminal Remote Looparound Test (#1201)
Note: This Test ABORTS
Voice and Control Channel Local Looparound Test
(#13)
Note: This Test ABORTS
Digital Line NPE Crosstalk Test (#9)
Note: This Test ABORTS
Digital Line Electronic Power Feed Test (#11)
DIG-LINE Station Lamp Updates Test (#16)
Station (Digital) Audits Test (#17)
*D = Destructive; ND = Nondestructive

Digital Line Electronic Power Feed Test(#11)

MM711 boards provide power to the terminals. Therefore this will be an EPF restore test. The
test procedure and its response is same as that of EPF. If the over current persists the power
will be shut off automatically and an EPF_off_overcurrent message is sent uplink.
Table 65: TEST#11 Digital Line Electronic Power Feed Test
Error
Test
Code
Result
ABORT
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
DIG-LINE (Digital Line)
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
Issue 1.1 June 2005
D/ND*
D
ND
ND
ND
ND
ND
1 of 2
155

Advertisement

Table of Contents
loading

This manual is also suitable for:

G350

Table of Contents