Port Audit Update Test (#36) - Avaya G250 Maintenance Manual

Media gateways
Hide thumbs Also See for G250:
Table of Contents

Advertisement

Port Audit Update Test (#36)

This test sends updates of the DID port translation for all ports on the media module that have
been translated. The update is non-disruptive and guards against possible corruption of
translation data contained on the media module. No response message is expected from the
media module once it receives translation updates. The port translation data includes:
Wink or immediate start trunk
Dial tone or rotary dialing trunk
Rotary dialing inter-digit timing
Network balance R/RC
Disconnect timing
Table 59: TEST #36 Port Audit Update Test
Error
Test
Code
Result
ABORT
1006
ABORT
2100
ABORT
FAIL
Description/ Recommendation
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals a maximum of 5 times.
The port is out of service, perhaps busied out.
Use display port GGGVSpp to determine the trunk group/member
number of the port. Use status trunk to determine the service state of
the port. If the port is out of service, wait until the port is in service and
idle before testing.
If the port status is in service and idle, then retry the command at
1-minute intervals a maximum of 5 times.
Could not allocate the necessary system resources to run the test.
Retry the command at 1-minute intervals a maximum of 5 times.
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
DID-TRK (Direct Inward Dial Trunk)
Issue 1.1 June 2005
1 of 2
145

Advertisement

Table of Contents
loading

This manual is also suitable for:

G350