Battery Feed Test (Also Called Port Diagnostic Test) (#35) - Avaya G250 Maintenance Manual

Media gateways
Hide thumbs Also See for G250:
Table of Contents

Advertisement

Battery Feed Test (also called Port Diagnostic Test) (#35)

The battery feed chip provides power to the telephone equipment, signaling, rotary dial pulsing,
transmission, and balance. This test checks the signaling and switchhook capabilities of the
battery feed chip by terminating the port, applying battery, and trying to detect a current.
Table 31: TEST #35 Battery Feed Test
Error
Test
Code
Result
ABORT
1000
ABORT
1004
ABORT
2000
ABORT
2100
ABORT
FAIL
PASS
Description/Recommendation
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
System resources required to run this test are not available. The port may
be reporting an external device alarm.
Enter test external-device-alarm port GGGVSpp to determine if the
port is reporting an EXT-DEV failure before retesting.
When the port has no EXT-DEV failure, retry the command at 1-minute
intervals for a maximum of 5 times.
The port received an EXT-DEV failure during the test. The test has been
aborted.
Enter test external-device-alarm port GGGVSpp to determine if the
port is reporting an EXT-DEV failure before retesting.
If the port has no EXT-DEV failure, retry the command at 1-minute
intervals for a maximum of 5 times.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
The port's battery feed chip is unable to supply sufficient power to sense
the external device alarm. This may occur when the test is performed at
the same time that the external device contact closure occurred.
Enter test external-device-alarm port GGGVSpp to determine if the
port is reporting an EXT-DEV failure before retesting. Wait until the port
has no EXT-DEV failure before retesting.
Retry the command at 1-minute intervals for a maximum of 5 times.
The port's battery feed chip is able to provide power to the external device
alarm to detect contact closure.
ALARM-PT (ALARM PORT)