Energy-Saving Control Function - Omron SYSDRIVE 3G3FV User Manual

High-function general-purpose inverter
Table of Contents

Advertisement

Advanced Operation
Group
Group
Function
Function
Options
O
o s
F1
PG Option Setup
F2
AI-14 Setup
F3
DI-08, 16 Setup
F4
AO-08, 12 Setup
F5
Not used
F6
Not used
F7
PO-36F Setup
F8
SI-F/G Setup
F9
CP-916 Setup
Terminal
e
a
H1
Digital Inputs
H2
Digital Outputs
H3
Analog Inputs
H4
Analog Outputs
H5
Not used
Protection
L1
Motor Overload
L2
PwrLoss Ridethru
L3
Stall Prevention
L4
Ref Detection
L5
Fault Restart
L6
Torque Detection
L7
Torque Limit
L8
Hdwe Protection
Operator
O e a o
o1
Monitor Select
o2
Key Selections

6-4-2 Energy-saving Control Function

The energy-saving control function is enabled when the energy-saving command (setting 63) has been
set in a multi-function input (H1-01 through H1-06). Inputting the energy-saving command while there is
a light load causes the Inverter's output voltage to be reduced and saves energy. Turn OFF the energy-
saving command when a normal load is added.
Parameter b8-01 determines the Inverter's output voltage when the energy-saving command is input.
Set this value as a percentage of the V/f pattern's voltage. Parameter L2-04 (the voltage recovery time)
determines the rate at which the output voltage is changed when the energy-saving command is turned
ON or OFF.
Parameter b8-02 determines the lower limit frequency for the energy-saving function. The energy-sav-
ing command is enabled only when the frequency reference is above this lower limit and the motor
speed is within the "speed agree" range.
Parameter settings for a PG Speed Control Card
Parameter settings for an Analog Command Card
Parameter settings for a Digital Command Card
Parameter settings for an Analog Monitor Card
(Do not change these settings.)
( o o c a ge
ese se
Parameter settings for a Pulse Monitor Card
Parameter settings for a SYSMAC BUS Interface
Card.
Parameter settings for a CompoBus/D Communica-
tions Card.
Function selection for multi-function inputs
Function selection for multi-function outputs
Adjustment/function selection for external analog
inputs
Adjustment/function selection for multi-function ana-
log outputs
(Do not change these settings.)
Sets electrical/thermal functions that protect the mo-
tor.
Selects the power-loss processing method.
Accel/Decel stall prevention settings and selection
Frequency detection settings and selection
Fault restart function settings
Sets overtorque detection functions 1 and 2
Not used. (Can't be set.)
Hardware overheating and phase loss protection
settings
Selects the Operator's display and setting methods.
Operator's key function selection and other parame-
ters
V/f
V/f
w/PG
---
OK
OK
OK
OK
OK
OK
OK
gs )
---
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
OK
OK
OK
OK
OK
OK
Chapter 6
Control mode
Open-loop
Flux
Vector
Vector
---
OK
OK
OK
OK
OK
OK
OK
---
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
6-37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents