Common Functions

This section summarizes the functions that can be used in common among the various
modes, and provides detailed explanations of their operations.

6-5-1 Summary of Common Control Functions

An "OK" in the control mode column indicates that the parameter can be changed in that control mode.
The functions that can be used in common are marked with a "S " and described in more detail later in
this section.
G oup
Group
Function
u c o
Application
ca o
b1
Sequence
b2
DC Braking
b3
Speed Search
b4
Delay Timers
b5
PID Control
b6
Reference Hold
b7
Droop Control
b8
Energy Saving
b9
Zero Servo
Tuning
u
g
C1
Accel/Decel
C2
S-Curve Acc/Dec
C3
Motor-Slip Comp
C4
Torque Comp
C5
ASR Tuning
C6
Carrier Freq
C7
Hunting Prev
C8
Factory Tuning
Reference
e e e ce
d1
Preset Reference
d2
Reference Limits
d3
Jump Frequencies
d4
Sequence
d5
Torque Control
Motor
o o
E1
V/f Pattern
E2
Motor Setup
E3
Control Method 2
E4
V/f Pattern 2
E5
Motor Setup 2
O
Options
o s
F1
PG Option Setup
F2
AI-14 Setup
F3
DI-08, 16 Setup
F4
AO-08, 12 Setup
F5
DO-02 Setup
F6
DO-08 Setup
F7
PO-36F Setup
F8
SI-F/G Setup
F9
CP-916 Setup
6-40
Comments
Co
S Settings such as the reference input method
S DC braking function settings
S Speed search function settings
S Timer function settings
S PID control settings
S Accel/deceleration time dwell function settings
Droop control settings
Multi-function input: Sets energy-saving control by ener-
gy saving reference.
Zero servo settings
Acceleration/deceleration time settings
S S-curve characteristics for accel/decel times
S Slip compensation function settings
S Torque compensation function settings
Speed control tuning
S Carrier frequency settings
Hunting prevention settings
Adjustment for open-loop vector control
Frequency reference settings (when using Operator)
S Frequency upper and lower limit settings
S Prohibited frequency settings
S Up/Down, Accel/Decel stop hold frequency setting
Torque control settings and tuning
S Motor settings
S
o o se
gs
S Control mode settings for second motor
S
S Parameter settings for second motor
a a e e se
gs o seco d
Parameter settings for a PG Speed Control Card
S Parameter settings for an Analog Command Card
S Parameter settings for a Digital Command Card
S Parameter settings for an Analog Monitor Card
Not Used. (Do not change these settings.)
o Used ( o o c a ge
S Parameter settings for a Pulse Monitor Card
S Parameter settings for a SYSMAC BUS Interface
Card.
S Parameter settings for a CompoBus/D Communica-
tions Card.
e s
o o
ese se
gs )
Chapter 6
Control mode
V/f
V/f
Open-loop
Flux
w/PG
Vector
Vector
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
---
OK
OK
OK
---
---
---
---
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
OK
---
OK
OK
OK
OK
OK
OK
OK
---
---
---
---
OK
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
OK
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
---
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK

Hide quick links: