Omron SYSDRIVE 3G3FV User Manual page 287

High-function general-purpose inverter
Table of Contents

Advertisement

Advanced Operation
Setting
0
No change. (Retain current settings.)
1
Record user defaults. (Record the current parameter settings as user defaults.)
2
Clear user defaults. (Clear the recorded user defaults.)
Parameter
Display name
p y
number
o2-04
Inverter Model #
Do not change this parameter setting; it is used by the manufacturer to identify the Inverter model.
The setting range and default setting depend on the Inverter capacity. The settings shown in the table
are for a 200-V class, 0.4 kW Inverter.
Parameter
Display name
p y
number
o2-05
Operator M.O.P.
This parameter determines whether it is necessary to press the Enter Key when changing the frequen-
cy reference with the Digital Operator's frequency reference monitor; it cannot be changed during op-
eration.
When o2-05 is set to 1 (Enter Key input not required.), the frequency reference changes simulta-
neously with the Digital Operator's value.
Setting
0
Enter Key input required.
1
Enter Key input not required.
Parameter
Display name
p y
number
o2-06
Oper Detection
This parameter specifies whether to stop operation when the Digital Operator is disconnected; it can-
not be changed during operation.
Setting
0
Disable Operator detection. (Continue operation when the Digital Operator is disconnected.)
1
Enable Operator detection. (Detect an OPR fault when the Digital Operator is disconnected, stop
the Inverter output, and operate the fault contact.)
Parameter
Display name
p y
number
o2-07
Elapsed Time Set
o2-08
Elapsed Time Run 0 or 1
Note These parameters cannot be changed during operation
Set the initial elapsed time in parameter o2-07. The elapsed operating time will start from this value.
Note When parameter o2-07 is set to the initial elapsed time, the accumulated operating time will be the
same as the value set in the parameter U1-13.
Function
Setting
g
Units
Default
range
setting
0 to FF
---
0
Setting
g
Units
Default
range
setting
0, 1
---
0
Function
Setting
g
Units
Default
range
setting
0 or 1
---
0
Function
Setting
g
Units
range
0 to 65535
h
0
---
0
Valid access levels
V/f
V/f with
Control
PG
Basic or Advanced
Valid access levels
V/f
V/f with
Control
PG
Advanced
Valid access levels
V/f
V/f with
Control
PG
Advanced
Default
Valid access levels
setting
V/f
V/f with
Control
PG
Advanced
Advanced
Chapter 6
Open Loop
Flux
Vector
Vector
Open Loop
Flux
Vector
Vector
Open Loop
Flux
Vector
Vector
Open Loop
Flux
Vector
Vector
6-113