Omron SYSDRIVE 3G3FV User Manual page 206

High-function general-purpose inverter
Table of Contents

Advertisement

Advanced Operation
Note 1. The setting units for parameters E1-04, E1-06, and E1-09 can be changed.
Note 2. This function is specific to flux vector control.
H Setting Motor Parameters
The motor parameters (function E2) will all be set automatically when auto-tuning is performed, so it
normally isn't necessary to set them manually. Set these parameters manually if auto-tuning can't be
completed properly. These parameters cannot be changed during operation.
Set the rated current (A) shown on the motor's nameplate.
Parameter
Display name
p y
number
E2-01
Motor Rated FLA 0.32 to 6.40
Note The setting range is 10% to 200% of the Inverter's rated output current. The default setting de-
pends upon the type of Inverter. (The table shows the default setting for 200-V class, 0.4-kW In-
verters.)
Calculate the rated slip (E2-02) from the value shown on the motor's nameplate with the following equa-
tion and set this value.
Rated slip = rated frequency (Hz) – rated speed (r/min)
Set the no-load current (E2-03) at the rated voltage and rated frequency. Normally this value isn't shown
on the motor's nameplate, so it might be necessary to contact the motor manufacturer.
Parameter
Display name
p y
number
E2-02
Motor Rated Slip
E2-03
No-Load Current
Note 1. The default setting depends upon the type of Inverter.
(The table shows the default settings for 200-V class, 0.4-kW Inverters.)
Note 2. The setting range is between 0.00 and 0.1 less than the Inverter's rated current.
Set the number of poles (E2-04) shown on the motor's nameplate.
Parameter
Display name
p y
number
E2-04
Number of Poles
Note Q: Quick Start, Basic, or Advanced
---: Not applicable.
Set the motor's terminal resistance between U and V, V and W, or W and U.
Usually the nameplate of the motor does not provide the motor's terminal resistance. Contact the motor
manufacturer for a test report on the motor's terminal resistance to set the following values.
Type E insulation:
Type B insulation:
6-32
Setting
Units
g
range
A
Setting range Units
g
g
0.00 to 20.00
0.00 to 2.90
(see note 2)
Setting
g
Units
range
2 to 48
---
Motor's terminal resistance ( ) at 75 C x 0.92
Motor's terminal resistance ( ) at 75 C x 0.92
Default
setting*
V/f
Control
1.90
Quick Start, Basic, or Advanced
number of poles/120
Default
setting*
V/f
Control
Hz
2.90
Advanced
A
1.20
Default
setting
V/f
Control
4
---
Chapter 6
Valid access levels
V/f with
Open Loop
PG
Vector
Valid access levels
V/f with
Open Loop
PG
Vector
Quick Start, Basic,
or Advanced
Valid access levels*
V/f with
Open Loop
PG
Vector
Q
---
Flux
Vector
Flux
Vector
,
,
Flux
Vector
Q