Advanced Operation
H Trim Control Level (d4-02)
This function sets the motor operated "trim" control level as a percentage of maximum output frequency
in units of 1%. When trim control increase and decrease are selected as multi-function contact input
functions (setting: H1__ = "1C" and "1D" respectively), the trim control level is added to or subtracted
from the analog frequency reference, when each respective contact closes.
Parameter
Display name
p y
number
d4-02
Trim Control Lvl
This parameter cannot be changed during operation.
If the minus speed command is ON and the result of the subtraction is beyond zero, the output frequen-
cy will become zero.
For information regarding the plus and minus speed commands, refer to the explanations of the multi-
function inputs (H1) in 6-5-7 External Terminal Function (H) .

6-5-5 Motor Parameters (E)

H Intermediate Output Frequency 2 and Intermediate Output Frequency
Voltage 2
For vector control of a special motor, such as a constant power-output motor or machine tool shaft mo-
tor, the motor may not fully operate in the constant output area (i.e., in frequency range as high as or
higher than the rated frequency).
If the high-performance control of the motor is required in the constant output area, V/f characteristics to
compensate for voltage increases caused by the motor inductance must be set.
These parameter settings are not required for normal motor control.
Parameter
Display name
p y
number
E1-11
Mid Frequency B
Parameter
Display name
p y
number
E1-12
Mid Voltage B
Parameter
Display name
p y
number
E1-13
Base Voltage
6-66
Setting
g
Units
Default
range
setting
0 to 100
%
25
Setting
g
Units
Default
range
setting
0.0 to
Times 0.0
400.0
Setting
g
Units
Default
range
setting
0.0 to
Times 0.0
255.0
(see
note)
Setting
g
Units
Default
range
setting
0.0 to
Times 0.0
255.0
(see
note)
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Advanced
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Advanced
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Advanced
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Advanced
Quick startup
Chapter 6
Flux
Vector
Vector
Flux
Vector
Vector
Flux
Vector
Vector
Flux
Vector
Vector