Omron SYSDRIVE 3G3FV User Manual page 355

High-function general-purpose inverter
Table of Contents

Advertisement

Maintenance Operations
Display
OPE07
Multi-function analog
Analog Selection
input selection error
OPE08
Function setting error
Function Setting
OPE10
V/f data setting error
V/f Ptrn Setting
OPE11
Parameter setting
CarrFrg /
error
On-Delay
ERR (flashing)
A verification error
EEPROM R/W Err
occurred when writing
EEPROM.
Meaning
The same setting (other than 1F) has been selected for H3-05
and H3-09.
A 3G3IV-PA114B Analog Reference Card is being used and
F2-01 is set to 0, but a multi-function input (H1-01 to H1-06) has
been set to Option/Inverter Selection (2).
Frequency Bias and Frequency Bias 2 are set at the same time.
Functions that cannot be controlled by the current control
mode are set. (For example, the torque reference was set in
V/f control.)
Parameters E1-04, E1-06, E1-07, and E1-09 do not satisfy the
following conditions:
E1-04 (F
One of the following parameter setting errors exists.
The carrier frequency upper limit (C6-01) > 5 KHz and
the carrier frequency lower limit (C6-02)
The carrier frequency gain (C6-03) > 6 and (C6-01) < (C6-02).
Try turning the power supply off and on again.
Try setting the parameters again.
Incorrect settings
)
E1-06 (F
) > E1-07 (F
MAX
A
Chapter 8
)
E1-09 (F
)
B
MIN
5 KHz.
8-13