Program Mode

The Inverter parameters can be set in program mode. The parameters which can be dis-
played and changed depend on the access level and control mode that are being used.
Refer to the following table to determine if a parameter can be changed.
S Parameter Groups
An "OK" in the control mode column indicates that the parameter can be changed in that control mode.
G oup
Group
Function
u c o
Application
ca o
b1
Sequence
b2
DC Braking
b3
Speed Search
b4
Delay Timers
b5
PID Control
b6
Reference Hold
b7
Droop Control
b8
Energy Saving
b9
Zero Servo
Tuning
u
g
C1
Accel/Decel
C2
S-Curve Acc/Dec
C3
Motor-Slip Comp
C4
Torque Comp
C5
ASR Tuning
C6
Carrier Freq
C7
Hunting Prev
C8
Factory Tuning
Reference
e e e ce
d1
Preset Reference
d2
Reference Limits
d3
Jump Frequencies
d4
Sequence
d5
Torque Control
Motor
o o
E1
V/f Pattern
E2
Motor Setup
E3
Control Method 2
E4
V/f Pattern 2
E5
Motor Setup 2
O
Options
o s
F1
PG Option Setup
F2
AI-14 Setup
F3
DI-08, 16 Setup
F4
AO-08, 12 Setup
F5
Not used (DO-02)
F6
Not used (DO-08)
F7
PO-36F Setup
F8
SI-F/G Setup
F9
CP-916 Setup
Comments
Co
e s
Settings such as the reference input method
DC braking function settings
Speed search function settings
Timer function settings
PID control settings
Accel/deceleration time dwell function settings
Droop control (speed drop) settings
Terminal input energy-saving control settings
Stop in the position loop
Acceleration/deceleration time settings
S-curve characteristics for accel/decel times
Slip compensation function settings
Torque compensation function settings
Speed control loop parameter settings
Carrier frequency settings
Hunting prevention function for V/f control
Adjustment for open-loop vector control
Operator frequency reference settings
Frequency upper and lower limit settings
Prohibited frequency settings
Hold for analog frequency reference
Parameter settings for torque control
Sets the motor's V/f characteristics.
Sets the motor parameters.
Sets the control method of motor 2.
Sets the V/f pattern of motor 2.
Motor setup for motor 2.
Parameter settings for a PG Card
Parameter settings for an Analog Reference Card
Parameter settings for a Digital Reference Card
Parameter settings for an Analog Monitor Card
Not Used. (Do not change these settings.)
o Used ( o o c a ge
ese se
Parameter settings for a Pulse Monitor Card.
SYSMAC BUS Interface card setup.
CompoBus/D (DeviceNet) communications card
setup.
Control mode
V/f
V/f
w/PG
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
OK
OK
---
---
OK
OK
OK
OK
OK
OK
OK
OK
---
OK
OK
OK
OK
OK
---
---
OK
OK
OK
OK
OK
OK
OK
OK
---
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
OK
OK
OK
OK
OK
OK
OK
gs )
---
---
OK
OK
OK
OK
OK
OK
Chapter 3
Open-loop
Flux
Vector
Vector
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
OK
---
---
---
OK
OK
OK
OK
OK
OK
OK
OK
---
---
OK
OK
OK
---
---
OK
---
OK
OK
OK
OK
OK
OK
OK
OK
---
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
OK
OK
OK
OK
OK
OK
OK
---
---
OK
OK
OK
OK
OK
OK
3-25