Omron SYSDRIVE 3G3FV User Manual page 286

High-function general-purpose inverter
Table of Contents

Advertisement

Advanced Operation
When the power is turned on, the frequency reference will appear in the Unit's data display if the de-
fault settings are being used. Any one of the four values monitored at startup (frequency reference,
output frequency, output current, or the value set in parameter o1-01) can be selected to appear when
the power is turned on. The value that appears automatically at startup is determined by parameter
o1-02 (Power-On Monitor).
Setting
Name
1
Frequency reference The frequency reference is displayed at start-up.
2
Output Frequency
3
Output Current
4
User Monitor
H Key Function Settings/Other Settings (o2)
Parameter
Display name
p y
number
o2-01
Local/Remote Key 0, 1
This parameter enables or disables the LOCAL/REMOTE Key (the Operation Mode Selector Key) on
the Digital Operator; it cannot be changed during operation.
Setting
0
Disabled.
1
Enabled. (Pressing the LOCAL/REMOTE Key switches control of operation between the
Operator and the sources specified in parameters b1-01 and b1-02.)
Parameter
Display name
p y
number
o2-02
Oper Stop Key
This parameter enables or disables the STOP on the Digital Operator; it cannot be changed during
operation.
Setting
0
Disabled. (The STOP Key is disabled when the run command is input from an external terminal.)
1
Enabled. (The STOP Key is enabled at all times during operation.)
Parameter
Display name
p y
number
o2-03
User Defaults
This parameter is used to record or clear the user defaults; it cannot be changed during operation.
Once the user defaults have been recorded, parameter A1-03 can be used to initialize the Inverter's
parameters to these defaults.
If the message "MAX Param Change" is displayed, the memory capacity is full. Reduce the number of
parameters that changed their default settings and register them again.
Note After the parameter o2-03 is set, the Digital Operator's display will return to 0 when parameter
registration processing is completed.
6-112
The output frequency is displayed at start-up.
The output current is displayed at start-up.
The value set in parameter o1-01 is displayed at start-up.
Setting
g
Units
Default
range
setting
---
1
Function
Setting
g
Units
Default
range
setting
0, 1
---
1
Function
Setting
g
Units
Default
range
setting
0, 1, or 2
---
0
Function
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Basic or Advanced
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Basic or Advanced
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Basic or Advanced
Chapter 6
Flux
Vector
Vector
Flux
Vector
Vector
Flux
Vector
Vector