3-7

Modified Constants Mode

The modified constants mode is used to display or change parameters that have been
changed from their factory-preset values.
When any parameters have been changed in program mode (b1-01 through o2-08),
pressing the Enter Key in modified constants mode will cause these parameters to be
displayed. (The initialize-mode parameters won't be displayed.)
S Modified Constants Mode Operations
In the following example, parameters C1-01 (acceleration time 1) and d1-01 (preset reference 1) have
been changed from their factory settings.
The settings for these two parameters are displayed and the setting for d1-01 is changed from
"60.00 Hz" to "30.00 Hz."
Key sequence
3-30
Display
Displays operation mode.
Displays modified constants mode.
Displays acceleration time 1 (C1-01).
Displays frequency reference 1 (d1-01).
Pressing Enter allows the setting to be changed.
(The leading digit will flash.)
Changes the setting to "30.00 Hz."
Writes the new setting.
Returns to the frequency reference 1 display.
Returns to the modified constants mode display.