Disabling Reverse Operation (B1-04); Selecting The Stopping Method (B1-03) - Omron SYSDRIVE 3G3FV User Manual

High-function general-purpose inverter
Table of Contents

Advertisement

Basic Operation
The "Multi-Accel/Decel 1" and "Multi-Accel/Decel 2" inputs will have priority when "Multi-Accel/Decel 1"
and "Multi-Accel/Decel 2" have been set in the multi-function inputs (H1-01 through H1-06).
Parameter
Display name
p y
number
C1-11
Acc/Dec SW Freq
Acc/Dec Time Switching Frequency
Acceleration/Deceleration Time 1 (C1-01 and C1-02) are used when the output frequency
Acceleration/Deceleration Time 4 (C1-07 and C1-08) are used when the output frequency < C1-11

5-1-6 Disabling Reverse Operation (b1-04)

Parameter b1-04 is used to enable and disable reverse command inputs. This parameter can be set to
"1" to disable reverse operation when necessary. This parameter cannot be changed during operation.
Parameter
Display name
p y
number
b1-04
Reverse Oper
Settings
Setting
Name
0
Reverse Enabled
1
Reverse Disabled

5-1-7 Selecting the Stopping Method (b1-03)

Parameter b1-03 sets the stopping method used when a stop command is input. This parameter cannot
be changed during operation.
Parameter
Display name
p y
number
b1-03
Stopping Method
Setting
g
Units Default
range (See
S
note.)
0.0 to 400.0
Hz
Output
frequency
(C1-11)
Setting
g
Units
range
0 or 1
---
Allows reverse operation.
Prohibits reverse operation.
Setting
g
Units
range
0 to 3
---
setting
V/f
Control
0.0
Advanced
Valid access levels
Default
setting
V/f
V/f with
Control
0
Basic or Advanced
Function
Valid access levels
Default
setting
V/f
V/f with
Control
0
Quick-start, Basic, or Advanced
Chapter 5
Valid access levels
V/f with
Open Loop
PG
Vector
Open Loop
PG
Vector
Open Loop
PG
Vector
Flux
Vector
C1-11
Flux
Vector
Flux
Vector
5-13