Basic Operation
H Presetting Frequency Reference Values (d1-01 through d1-09)
Parameters d1-01 through d1-08 contain preset reference values 1 through 8. The setting range for all
of the values is 0 to the max. frequency. These 8 parameters can be changed during operation.
Parameter
Display name
p y
number
d1-01
Reference 1
d1-02
Reference 2
d1-03
Reference 3
d1-04
Reference 4
d1-05
Reference 5
d1-06
Reference 6
d1-07
Reference 7
d1-08
Reference 8
Note 1. The units for these values are set in o1-03.
Note 2. The frequency reference's initial value and set value will change when o1-03 is changed.
For example, if preset reference 1 is set to 6.00 Hz and o1-03 is changed to 1 (0.01% units),
the setting for preset reference 1 will become 10.00%.
Note 3. When using preset references 2 through 8, be sure to set Multi-Step Reference 1, 2, and 3 in
the multi-function inputs (H1-01 through H1-06) as required.
When using the Jog function, set the jog frequency reference in parameter d1-09. The setting range for
this value is 0 to the max. frequency. This parameter can be changed during operation.
Parameter
Display name
p y
number
d1-09
Jog Reference
Note 1. When performing the Jog operation from an external terminal, set the multi-function inputs
(H1-01 through H1-06) to "Jog Frequency Reference," "Forward Jog," or "Reverse Jog" as
required.
Note 2. The multi-function input setting is unnecessary when performing the Jog operation from the
Operator.

5-1-4 Run Source and Responsiveness Settings

H Selecting the Run Source (b1-02)
Parameter b1-02 is used to select the source of the run command; it cannot be changed during opera-
tion. When a control circuit terminal (external terminal) is set, the Unit operates with 2-wire forward/stop
and reverse/stop control. (When the Unit has been initialized for a 3-wire control or a multi-function input
is set to "0" (3-wire control), the Unit operates with 3-wire run, stop and forward/reverse control.)
Parameter
Display name
p y
number
b1-02
Run Source
5-10
Setting
g
Units
Default
range
setting
0 to max.
o1-03 6.00 Hz
0 to max.
o1-03 0.00 Hz
0 to max.
o1-03 0.00 Hz
0 to max.
o1-03 0.00 Hz
0 to max.
o1-03 0.00 Hz
0 to max.
o1-03 0.00 Hz
0 to max.
o1-03 0.00 Hz
0 to max.
o1-03 0.00 Hz
Setting
g
Units
Default
range
setting
0 to max.
o1-03 6.00 Hz
Setting
g
Units
Default
range
setting
0 to 4
---
1
Valid access levels
V/f
V/f with
Control
PG
Quick-start, Basic, or Advanced
Quick-start, Basic, or Advanced
Quick-start, Basic, or Advanced
Quick-start, Basic, or Advanced
Basic or Advanced
Basic or Advanced
Basic or Advanced
Basic or Advanced
Valid access levels
V/f
V/f with
Control
PG
Quick-start, Basic, or Advanced
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Quick-start, Basic, or Advanced
Chapter 5
Open Loop
Flux
Vector
Vector
Open Loop
Flux
Vector
Vector
Flux
Vector
Vector

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents