Setting the V/f Pattern
When auto-tuning has not been executed correctly (i.e., when "Tune Aborted" is displayed), switch the
control mode to "V/f control" and set the V/f pattern.
Procedure for changing the control mode.
Key sequence
2 times
2 times
Set the control mode to "V/f control," and then set the following three items. These parameters cannot
be changed during operation.
Parameter
Display name
p y
number
E1-05
Max Voltage
Parameter
Display name
p y
number
E1-06
Base Frequency
Parameter
Display name
p y
number
E2-01
Motor Rated FLA 10 to
Note 1. Inverter rated current ratio.
Note 2. The default setting for rated current differs according to the type of Inverter.
Display
Displays operation mode.
Displays initialize mode.
Puts the Unit in initialize mode. (Select Language
display)
Press the Up Arrow Key and the control mode select is
displayed.
Control mode select (A1-02) is displayed.
Selects open-loop vector control.
The set values are overwritten.
Returns to the control mode select display.
Returns to the operation mode display.
Setting
g
Units
Default
range
setting
0.0 to
VAC
200.0
255.0
(400.0)
(0.0 to
510.0)
Setting
g
Units
Default
range
setting
0.0 to
Hz
60.0
400.0
Setting
g
Units
Default
range
setting
A
See
200%
note 2
(See
note 1)
Explanation
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Quick-start, Basic, or Advanced
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Quick-start, Basic, or Advanced
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Quick-start, Basic, or Advanced
Chapter 4
Flux
Vector
Vector
Flux
Vector
Vector
Flux
Vector
Vector
4-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents