Omron SYSDRIVE 3G3FV User Manual page 87

High-function general-purpose inverter
Table of Contents

Advertisement

Preparing for Operation
H Parameter Setting Levels (Partial)
MENU
Operation mode
Initialize mode
Program mode
[Mode]
H Setting the Parameter in the Quick-start Access Level
The parameter level will be displayed when the Enter Key is pressed at the program mode display.
Key sequence
2 times
2 times
---
Application
b1 Sequence
Parameter to be changed
Tuning
C1 Accel/Decel
Reference
C2 S-Curve Acc/Dec
[Group]
Display
Displays operation mode.
Displays program mode.
Puts the Unit in program mode.
Displays the b1-01 Reference source selection.
Displays the b1-02 Run source selection.
Displays the b1-03 Stopping method selection.
Displays C1-01 Acceleration time 1.
Selects the parameter so that the leading 0 flashes.
(The digit that can be changed flashes.)
Moves the cursor so that the "1" digit flashes.
Changes the 1 to a 2.
Writes the new setting.
Returns to the C1-01 Acceleration time 1 display.
Returns to the program mode display.
[Function]
Explanation
Chapter 3
b1-01 Reference source
b1-02 Run source
b1-03 Stopping method
C1-01 Accel Time 1
C1-02 Decel Time 1
[Parameter]
3-7