The relation between these parameters is shown in the following diagram.
Output frequency

6-5-3 Tuning Parameters (C)

H Setting the S-curve Characteristic Function (C2)
Using the S-curve characteristic function for acceleration and deceleration can reduce shock to the
machinery when stopping and starting.
With the SYSDRIVE 3G3FV, S-curve characteristic times can be set respectively for beginning accel-
eration, ending acceleration, beginning deceleration, and ending deceleration.
Parameter
Display name
p y
number
C2-01
SCrv Acc @ Start 0.00 to
C2-02
SCrv Acc @ End
C2-03
SCrv Dec @
Start
C2-04
SCrv Dec @ End 0.00 to
These parameters cannot be changed during operation.
The relation between these parameters is shown in the following diagram.
Output frequency
6-58
b6-01
b6-02
Setting
g
Units
Default
range
setting
Sec
0.20
2.50
0.00 to
Sec
0.20
2.50
0.00 to
Sec
0.20
2.50
Sec
0.20
2.50
b6-03
b6-04
Valid access levels
V/f
V/f with
Open Loop
Control
PG
Advanced
Advanced
Advanced
Advanced
Chapter 6
Time
Flux
Vector
Vector
Time