Chapter 2: Installation

Rack-mounting the BlueSecure Controller

You may install the Bluesocket BSC in any two-post equipment rack or cabinet that
conforms to ANSI/EIA-310-D-92 specifications.
Note: The BSC should not have desktop feet, bumpers, or a chassis cap installed when
mounted in an equipment rack. If these are installed, remove them prior to rack-mounting.
Follow these steps to mount the Bluesocket BSC in a two-post equipment rack:
Using a #2 Phillips-head screwdriver and the eight supplied #8-32 Phillips-head
1.
screws, attach the mounting brackets to the sides of the BSC chassis as shown in
Figure 2-8.
Note: Connect the mounting brackets only to the front of the BSC-600 or BSC-1200
chassis. You can attach the mounting brackets to either the front or rear of the BSC-
2100, BSC-2200/3200/5200 chassis depending on the cable access you prefer.
Position the BSC in your equipment rack.
2.
Secure the BSC's mounting brackets to the rack rails using the appropriate hardware.
3.
After rack-mounting the BSC chassis, connect the BSC to your network as described in
"Connecting the BlueSecure Controller to Your Network" on page 2-13, and then power
2-12

Figure 2-7: Attaching the BSC-2100/5200 Chassis Cap

Figure 2-8: Attaching the Mounting Brackets to the BSC Chassis