Chapter 15: Status
Associations - Wireless clients that have associated to the BSAP. Click (+) to expand
the list of associations or (-) to collapse the list.
Count - Number of associations to the BSAP.
Channel - Channel on which BSAP's 802.11a/n and 802.11b/g/n radios are
operating.
Tx Power - Transmission power settings for the BSAP 802.11a/n and 802.11b/g/n
radios.
ESSID - Extended Service Set Identifier used to identify wireless clients associated to
the BSAP.
Security - Configured security (WEP, WPA, etc.) associated with the BSAP's SSID.
Type - BAP, i.e., BlueSecure Access Point.
Adjacent APs - MAC address of APs within range of the BSAP. Click (+) to expand the
list of associations or (-) to collapse the list.
Adjacent Count - Number of APs within range of the BSAP.
Self Channel Load - Indicates the cumulative mean percent load saturation of the
current radio channel by clients connected to this AP.
Other Channel Load - Indicates the cumulative mean percent load saturation of the
current radio channel by clients connected to other APs but on the same channel.
Non 802.11 Interference - The number of seconds since significant non-802.11
interference was detected (e.g. microwave oven interference).

Monitoring RF IDS Alarms

Click the Status tab in the BSC administrator console, click the Active Connections tab,
and then click the RF IDS link to list the alarms received from BSAPs operating in Sensor
mode connected to the BSC. The RF IDS Alarms page appears as shown in Figure 15-4
The following information is provided about received alarms:
Note: An alarm is listed just once, regardless of the number of sensors that have detected
this alert. Any alarm detected by more than one sensor has a plus icon next to each of the
visible Sensor (MAC|IP|Location) fields. Clicking on any of these plus icons expands to
the complete list of sensors on all visible columns for that alarm. If any of the Sensor Mac,
15-6

Figure 15-4: Received Sensor Alarms