V.8/V.34 Control Procedure - Canon G3 Error Code List

Hide thumbs Also See for G3:
Table of Contents

Advertisement

Appendix

2.3 V.8/V.34 Control Procedure

Calling Side (transmitter)
Network interaction
(Phase 1)
Probing
(Phase 2)
Primary channel
equalizer training
(Phase 3)
Control channel
start-up
(Phase 4)
Control channel
Primary channel
resyncronization
procedure
Image data
Control channel
resyncronization
procedure
(Communication end
procedure)
Line disconnected
Called Side (receiver)
Dial
CNG
V.8
ANSam
CM
JM
CJ
INFO0c
INFO0a
A
B
A
B
L1
L2
A
B
INFO0h
S
S
PP
TRN
PPh
PPh
ALT
ALT
MPh
MPh
MPh
MPh
E
E
NSF
flags
CSI
DIS
V.34
NSS
flags
TSI
DCS
CFR
flags
flags
"1"
S
S
PP
B1
Image
data
Turn-Off
Sh
Sh
Sh
Sh
ALT
ALT
E
E
PPS-EOP
flags
MCF
flags
flags
DCN
"1"
Figure 4 V.8/V.34 Control Procedure
A-4
Declares the usable modulation mode.
Declares that V.34 capability exists on
each machine, and transfers the V.34
procedures with phase 2.
After declaring the modem's modulation
speed capacity, etc. to each machine,
the receiving side determines the
modulation speed based on the results
of a probing signal output by the
transmitting side.
The transmitting side outputs a training
signal to determine the image transmission
speed.
The optimum image transfer speed is
determined by the condition in which the
training signal is received.
The pre-message protocol is done in the
same way as a normal T.30, at 1200bps.
The training signal is output with the
determined parameters, and continues to
transmit the image data.
The post-message protocol is done in the
same way as a normal T.30, at 1200bps.
Line disconnected