Diagnostics and Troubleshooting
Error code
126.11
126.14
L L V V P P S S S S e e r r v v i i c c e e C C h h e e c c k k
Action
Step 1
Make sure that the printer is
directly plugged into the electrical
outlet.
Does the problem remain?
Step 2
Make sure that the voltage output
of the electrical outlet matches
the voltage rating of the printer.
Does the problem remain?
Step 3
1 Make sure that the PCN1 cable
on the LVPS is properly
connected.
2 Make sure that the JLVPS1
cable on the controller board is
properly connected.
Does the problem remain?
Step 4
Make sure that the voltage output
of the electrical outlet matches
the voltage rating of the LVPS.
Does the problem remain?
Step 5
Perform a POR.
Does the problem remain?
100
Xerox
B310 Printer
®
Service Manual
Description
Line frequency exceeded the
operating range.
LVPS relay is stuck or closed.
Yes
Go to step 2.
Go to step 3.
Go to step 4.
Go to step 5.
Go to step 6.
Action
No
The problem is solved.
The problem is solved.
The problem is solved.
The problem is solved.
The problem is solved.