1. PLC Development Environment Using GX Developer
(3) Editing of integrated type interlinear statements
(a) Circuit display
On the circuit display screen that shows the integrated type interlinear statements, double-
clicking the interlinear statement you want to edit displays the following dialog. Perform editing
operation on the dialog and click [OK] or press [Enter].
(b) List display
On the list display screen, double-clicking the interlinear statement you want to edit displays the
following dialog. Perform editing operation on the dialog and click [OK] or press [Enter].
(c) Entering new message data
• Displaying new edit screen
Perform the following operation to display the [New] dialog, and set the [Data name] and
[Title]. After setting, click [OK].
[Project] → [Edit Data] → [New]
• Changing to list display mode
Perform the following operation to display the list data.
[View] → [Instruction list]
• Entering message data
Press "Enter" on the "END" line, enter data as in "(b) List display", and then press "Enter" on
the next line and enter message data.
1.4 Creating PLC-related Data
- 38 -