(2) Devices which can be index-qualified
With the exception of the restrictions noted below, index qualification can be used with devices
used with contacts, coils, basic commands, and application commands.
(a) Devices which cannot use index qualification
Device
K, H
P
Z
T
C
(b) Devices in which the index resistors are restricted
Device
T
C
For the current value of a timer and a counter, index resistor No. is not restricted.
X0
M100
X1
M100
(c) Others
1) Bit data
Device number can be index-qualified when performing digit designation.
However, index qualification is not possible for digit designation.
BIN
6. Explanation of Commands
6.2 Command Formats
Meaning
32-bits constant
Pointer used as labels
Index register
Timer setting value, coil
Counter setting value, coil
Meaning
Z0 or Z1 can use only to timer
contact.
Z0 or Z1 can use only to counter
contact.
K100
T0
BCD T0Z4
K4Y30
K10
C100
BCD C100Z6
K0Y40
K4X0Z2
D0
BIN K4Z3X0
D0
- 99 -
Get other manuals https://www.bkmanuals.com
Example
T0Z0
T1
C0Z1
C1
Timer setting value
(Cannot use index qualification)
Timer current value
Counter setting value
(Cannot use index qualification)
Counter current value
Setting that enables device number
index qualification
If Z2 = 3, then X(0+3) = X3
Setting that cannot enable digit
designation index qualification
K100