Mitsubishi Electric MELDAS C6 Programming Manual page 364

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

(1) Rotary body indexing
Direction of rotation and number of steps of ATC magazine (or turret) are determined
automatically.
ACT
S.ROT
Index command
Rp (parameter) contents
15
14
F
E
Error output
0: Normal completion
1: Error completion
(Note 1) The Index command is executed after setting R numbers to Rn to Rn+3 and writing data in
the file registers (Rs) each corresponding to the R numbers. However, data setting to the
parameter (Rp) is done once before execution of the Index command; this is to prevent the
error code from being cleared.
(Note 2) The error code stored in bit F of the parameter (Rp) is not cleared even if the Index
command activating signal (ACT) goes off.
10. Exclusive Commands 2
10.2 S.ROT Commands
Rp
Rn
Rn+1
Rn+2
Rn+3
K1
R n
R m
Mm
(Note) CW or CCW output is controlled so that it
takes a short circuit regardless of parameter
specification.
Number of rotary body indexing
cycles designating R number
Control buffer data position
designating R number
7
6
5
4
3
(Spare)
4
3
0,0:(Step No. +1) is counted.
0,1:Step No. is counted.
1,0:(Step No. -1) is counted.
  
(When the current value is equal to the target value, -1 will apear.)
- 355 -
Get other manuals https://www.bkmanuals.com
Parameter setting R No.
Current position R No.
Target position R No.
Output R No.
0: Direction of rotation CW
1: Direction of rotation CCW
2
1
0
0: Rotary body starts from 1
1: Rotary body starts from 0
0: Direction of rotation is determined
for shorter reach.
1: Direction of rotation is not determined
for shorter reach.
Indirect
designation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64

Table of Contents