Appendix 3. PLC Development Environment using GPPQ
3.5.2 Ladder Transfer to the C64 Controller
The method of transferring a ladder to the C64 controller with the GPPQ (especially the restrictions
and C64 characteristic operations) is explained below.
(1) Menu Selection
The screen is selected from the menu using the following GPPQ basic operation.
Alt
Mode screen
(2) Screen Operation
The required options are selected and executed on the following screen.
[Write to PC]
Interface
RS232C
Target PC
Network : 0
Target Mem
Internal RAM
1. File 1. File Name [
2. Tgt
1. [ * ] Parameter
2. [ * ] Seq/SFC Prog
3. [ ] Device Comment
4. [ ] Dev Init Value
5. [ ] Simulation Data
6. [ ] File Register
1. [ ] Internal
2. Device Mem
[Restrictions]
The following options of [2. Tgt] under [1. File] can be selected.
[1. Parameter]
[2. Seq/SPC Prog] and [1. Whole Range]
[3. Device Comment]
Note that nothing will be transferred even if [1. Parameter] is selected.
3.5 PLC Program Development Procedure
PC menu
( GRPH )
2
window
Menu
PC
<--->
QnACPU
Station : FF
Title [
]
Title [
1. ( * ) Whole Range
2. ( ) Step Range
3. ( ) Step Range
4. ( ) Block Range
1. ( * ) Whole Range
2. ( ) Specify
1. ( * ) Whole Range
2. ( ) Specify Detail Range
Cancel(N)
Execute(Y)
Ctrl+L : filelist Ctrl+D : directo Space : sele Esc : close