Mitsubishi Electric MELDAS C6 Programming Manual page 314

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

Execution conditions
The execution conditions for FROM, TO are as shown below.
Command
FROM
TO
Program example
(1) To read 32 words of data in Area 2 of the FL-net unit (buffer memory address 2000H) and write
them into D0 to D31 of data register. (When the I/O number of FL-net unit is 000.)
FROM
10
(2) To write 32 words of data in data register D1000 to D1031 into the buffer memory addresses
2040H to 205FH of FL-net unit's Area 2. (When the I/O number of FL-net unit is 000.)
10
9. Exclusive Commands 1
FROM, TO
ON
OFF
Executed per scan
Executed per scan
H0
H2000
D0
TO
H0
H2040 D1000
- 305 -
Get other manuals https://www.bkmanuals.com
Coding
No. of
Com-
K32
steps
mand
10
LD
11
FROM H0
16
Coding
No. of
Com-
K32
steps
mand
10
LD
11
TO
16
Device
H2000
D0
K32
Device
H2040 D1000
H0
K32