Mitsubishi Electric MELDAS C6 Programming Manual page 132

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

Execution condition
This is executed per scan regardless of the operation results before the OUT command.
Program example
(1) Program to turn ON Y10 and Y14 ten seconds after X0 turns ON.
X0
10
T1
14
(2) Program to use X10 to 1F BCD data as timer setting value.
X0
10
X2
14
T2
18
7. Basic Commands
OUT (T)
T1 K100
Y10
Y14
BIN
K4X10
D10
T2 D10
Y15
- 123 -
Get other manuals https://www.bkmanuals.com
Coding
No. of
Com-
steps
mand
10
LD
11
OUT
14
LD
15
OUT
16
OUT
17
The X10 to 1F data is BIN converted and
stored in D10.
If X2 turns ON, the data stored in D10 will be
counted as the setting value.
W hen T2 counts up, Y15 will turn ON.
Coding
No. of
Com-
steps
mand
10
LD
X0
11
BIN
K4X10 D10
14
LD
X2
15
OUT
T2
18
LD
T2
19
OUT
Y15
20
Device
X0
T1
K100
T1
Y10
Y14
Device
D10