SET ... Device setting (ON)
Bit device
X
Y
M
L
F
B SB T SM V T
D
(Note) In the modification of index, 2 steps are used for B or SB device.
Setting command
Function
(1) The designated device turns ON when the SET input turns ON.
(2) The device turned ON remains ON even if the SET input turns OFF. The device can be turned
OFF with the RST command.
X5
X7
(3) If the SET input is OFF, the state of the device will not change.
Execution condition
The execution conditions for the SET command are as shown below.
SET input
SET (Y, M, L, SM, F)
7. Basic Commands
SET
Usable device
Word device
C D R W SW Z SD K
X5
OFF
SET Y10
X7
OFF
RST Y10
Y10
OFF
ON
OFF
Executed per scan
- 126 -
Get other manuals https://www.bkmanuals.com
Con-
Pointer
stant
H
Setting data
SET
D
Device N0. to
D
be set (ON)
ON
ON
ON
Executed per scan
Digit
No. of
desig-
Index
steps
nation
P
1/2